Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 99 of 99 items found.

  • Power Supply, 12.5V, 120A, 1500W

    N5763A - Keysight Technologies

    Keysight basic DC power supplies offer essential features for a tight budget. The Keysight 1500W, single output N5763A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current. It delivers solid performance and a variety of basic and enhanced capabilities in a compact 1U package.

  • Power Supply, 6V, 180A, 1080W

    N5761A - Keysight Technologies

    Keysight basic DC power supplies offer essential features for a tight budget. The Keysight 1080W, single output N5761A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current. It delivers solid performance and a variety of basic and enhanced capabilities in a compact 1U package.

  • 3-Phase AC Power Source

    61700 series - Chroma ATE Inc.

    The Chroma Programmable AC Power Source model 61700 series delivers pure, 5-wire, 3-phase AC power. Unlike the traditional 3-phase AC power source, it includes low power rating models at very low cost. Users can program voltage and frequency, measure the critical characteristics of the output on its LCD display. It delivers the right solution to simulate all kinds of input condition of UUT to be utilized in R&D and QA. It is also suitable for commercial applications from laboratory testing to mass productions. The 61700 supplies the output voltage from 0 to 300VAC and it can be set individually for each phase. Users also can set the phase angle from 0? to 360?. These kinds of function make the 61700 series can simulate unbalance 3-phase power. Because of the wide output frequency from 15 to 1200Hz, it is suitable for avionics, marine and military application. The AC+DC mode extends the output function to simulate abnormal situation when power line contains DC offset.

  • High Voltage Film Capacitor

    STHVP/STHVE - HK Film Capacitor Ltd

    High Voltage Pulse Current for medium frequency applicationHigh Voltage DC / AC Voltage applicationCapacitor can be discharged at rated voltage directly without any protective component and with ambient Temperature up to +105CHigh Voltage Decoupling and SnubberingVoltage MultiplierInduction heatingAct as discharge capacitor to trigger laser, X-Ray and Tesla CoilFor high voltage capacitor bank or arrayHigh Voltage Power Supplies

  • AC / DC Electronic Loads – Benchtop Testing to Automated Test Systems

    Chroma Systems Solutions, Inc.

    Chroma is the global leader in Electronic Load manufacturing. Chroma’s AC Electronic Loads are designed for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources, and other power devices such as switches, circuit breakers, fuses and connectors. Chroma’s DC Electronic Loads are used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, and fuel cell testing. Chroma loads can do it all including full current down to 0.4VDC, CZ mode, user defined waveforms, timing measurements, and 3 current ranges per load. Chroma’s electronic loads come standard with either USB or RS232 ports for control and can be configured for GPIB (IEEE-488) control as well.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Power Electronics Test

    Sample Technology

    Aiming at the problem of PI, Shengbo Technology carefully studied the root cause of the problem. Through the loop analysis and noise analysis of power supply and automatic control, it provided targeted solutions for frequency response analyzer and power supply rejection ratio (PSRR) analysis . In addition, we also have a professional technical application support team in the field of power electronics testing. We can customize and develop the corresponding system software for customers so that it can be applied to PC / Servo / Telecom power supplies, adapters and chargers, and backlights. Inverter, LED drivers, ballasts for energy-saving lamps (Ballast), and even UPS, PV Inverter, electric vehicle chargers, AC and DC motors, etc.

  • Adjustable Isolating Transformers

    PeakTech Prüf- und Messtechnik GmbH

    The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

Get Help